# How to read a sealant technical data sheet (TDS)

URL: https://sentaproducts.com/blog/how-to-read-a-technical-data-sheet/
Español: https://sentaproducts.com/es/blog/como-leer-una-ficha-tecnica-de-sellador/
Português: https://sentaproducts.com/pt/blog/como-ler-a-ficha-tecnica-de-um-selante/

Published: 2026-06-26 · Updated: 2026-11-19

A section-by-section guide to the sealant technical data sheet: skin time, cure rate, hardness, movement, temperatures and the limitations not to skip.

A sealant technical data sheet (TDS) tells you what the product is, what it sticks to, how it behaves while curing and once cured, and where it should not be used. Read the limitations and application conditions first, then check the performance numbers against your joint. This guide walks through each section using real values from [Senta 100% RTV Silicone](/products/white-100-rtv-silicone/).

## Sealant technical data sheet vs. safety data sheet

- **Technical data sheet (TDS):** performance and application. What it is, what it's for, how to apply it, test results and limitations.
- **Safety data sheet (SDS):** health and safety. Hazards, protective equipment, first aid, storage, spill handling and transport.

You need both. The TDS helps you pick and apply the product; the SDS tells you how to handle it safely. Senta's are both on the technical documents page.

## 1. Product description and uses

The first block names the chemistry and the main applications. For Senta silicone, that's a one-component, 100% acetoxy RTV (room-temperature vulcanizing) silicone that cures with moisture in the air. "Acetoxy" tells you right away it releases a vinegar smell while curing, which matters for ventilation and for which surfaces it suits.

Look here for the intended uses and the substrates it bonds to. Senta silicone lists adhesion to glass, aluminum, metals, wood and most common non-porous building materials.

## 2. Limitations: read this before anything else

This is the section people skip and later regret. For Senta silicone, it says:

- Not for porous natural stone (marble, granite and other natural stone), concrete or other porous surfaces
- Do not use on mirrors or on copper, brass, lead or other sensitive metals
- Not paintable
- Not for totally confined spaces
- Not for use with bitumen, neoprene and certain organic elastomers
- Can yellow if exposed to bleach or HCl-based brick cleaners while curing

If your job hits any of these, choose a different product rather than hoping it works out.

## 3. Uncured properties: how it behaves on the job

These numbers describe the working window.

- **Skin time:** how long until a surface skin forms. Senta: 8–20 minutes at 70 °F and 50 % relative humidity. Warmer, more humid air shortens it; cold, dry air lengthens it.
- **Tooling time:** how long you have to smooth the bead. Senta: tool within 5 minutes.
- **Sag or slump:** whether it holds in vertical joints. Senta: 0 in (ISO 7390).
- **Cure rate:** how fast it cures through. Senta: 1/8 in of bead depth per 24 hours. A deeper bead takes longer, which is one reason joint depth matters.

Note the test conditions. A skin time measured at 70 °F and 50 % RH won't be the same on a 45 °F morning.

## 4. Cured properties: what it does once set

- **Tensile strength:** how much pull the cured rubber takes before breaking. Senta: ≥ 215 psi (ASTM D412).
- **Elongation at break:** how far it stretches before tearing. Senta: ≥ 350 % (ASTM D412).
- **Shore A hardness:** how soft or firm the cured bead is. Senta: 15–25 after 28 days. Lower numbers are softer and more flexible.
- **Movement capability:** how much the joint can expand and contract. Senta: ±25 % (ASTM C920 Class 25).
- **Service temperature:** the range the cured sealant tolerates. Senta: -62 °F to 400 °F, 450 °F intermittent.

Pay attention to the "≥" sign. It means the value is a minimum, not a typical average.

Elongation and movement capability are not the same thing. Elongation is a lab pull-to-break number; movement capability is what the sealant handles repeatedly in a real joint. Design your joint around the movement class.

## 5. Application conditions and joint design

- **Application temperature:** Senta silicone: 40–105 °F.
- **Surface prep:** clean, dry, free of dust, oil and old sealant.
- **Joint dimensions:** Senta recommends a joint depth of about half the width (2:1 width to depth), 0.24 in depth for joints 0.24–0.47 in wide, and a minimum of 5 × 5 mm.

Our guide to [joint size and backer rod](/blog/joint-size-and-backer-rod/) explains why these ratios matter.

## 6. Standards and compliance

This lists the specs the product meets. Senta silicone: ASTM C920 Type S, Grade NS, Class 25; CE EN 15651 (façade, glazing, sanitary); MIL-A-46106A; TT-S-00230C; TT-S-01543A; and LEED EQc4.1 / SCAQMD Rule 1168 compliant. If you need to decode the ASTM line, see [ASTM C920 explained](/blog/astm-c920-explained/).

## 7. Packaging, storage and shelf life

Senta silicone comes in a 10.1 fl oz (300 ml) cartridge, 24 per case, with an 18-month shelf life unopened when stored dry between 40 °F and 105 °F. Check the date before a big job.

## A quick checklist before you buy

1. Does the limitations section rule out any surface on this job?
2. Is the application temperature range realistic for the day you'll work?
3. Does the movement class fit the joint?
4. Can you get the right width-to-depth ratio?
5. Will it need to be painted?
6. Do you have the SDS for the crew?

## FAQ

### What's the difference between skin time and cure time?

Skin time is when the surface stops being wet to the touch. Cure continues inward afterward; for Senta silicone, at about 1/8 in of depth per 24 hours.

### Why do some TDS values have a "≥" sign?

It means the number is a guaranteed minimum. Senta lists tensile strength ≥ 215 psi and elongation ≥ 350 % this way.

### Where can I download Senta's TDS and SDS?

Both are on the technical documents page.

Download the current Senta data sheets from the [technical documents page](/technical/).